We provide Professional Civil and Structural Engineering Consultancy to our customer as below:-

  1. Renovation and Extension Plans Submission to Authorities.
  2. Infrastructure (Sewerage, Drainage, Road & Water Supply).
  3. RC Structure (Residential, Commercial & Industrial).
  4. Professional Endorsement after reviewing.
  5. Preparing as-built drawings and PE endorsement.
  6. Project Management Consultant Services.
  7. Value Engineering and cost optimization.
  8. Telecommunication Towers.
Subscribe to sarapandian

Powered by us.groups.yahoo.com

Sunday, May 8, 2011

Sealing To Moving Concrete Cracks

movable crack sealing

I. TYPE OF DEFECTS
Type of defects: Non-structural and movable cracks.
II. SURFACE PREPARATION
  • The cracks and adjacent substrate must be clean, sound and free of contaminated material. Remove dust, laitance, grease, curing compounds and other bond inhibiting materials from surface by mechanical means.
  • “V” notch the surface of crack with mechanical router or hand chipping to maximum width of 8 mm and to minimum depth of 8 mm.
III. SEALING
  • Material: Sikaflex Construction (J)
  • To ensure the cleanliness of the substrate, use high pressure air compressor to clean the substrate from any dust and loose particle.
  • In case there is possibility of the sealant adheres to the bottom of the joints then a backer rod with diameter min. 20 % bigger than the width of joint shall be applied.
  • The application of Sika Primer 3 is recommended
  • Gun Sikaflex Construction (J) into prepared crack to a minimum depth of 8 mm.
  • Allow sealant to cure for at least 24 hours before the application of elastic water dispersed paint.

Popular Posts